電源 (Zippy)

    S1M-5550V(550W)

    製品仕様

    wattage550W
    solutionServer ,Workstation ,Storage System
    dimension_mm247.9x106x40
    dimension_inch9.76x4.17x1.57
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:4A(RMS)FOR 230VAC, 8A(RMS)FOR 115VAC INRUSH CURRENT:60A MAX. FOR 115 VAC PER MODULE, 80A MAX. FOR 230 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0 32 ±5% ±1% 60mV
    +12V 2 45 ±5% ±1% 120mV
    -12V 0 1 ±5% ±1% 120mV
    +3.3V 0 25 ±5% ±1% 60mV
    +5VSB 0.1 3.5 ±5% ±1% 60mV


    features* TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~80℃
    * HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
    * EFFICIENCY:TYPICAL 80% AT 115V, 82% AT 230V,AT FULL LOAD
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
    * OVER POWER PROTECTION:110~160% MAX
    * OVER VOLTAGE PROTECTION:+5V→5.7V~6.5V,+3.3V→3.7V~4.1V ,+12V→12.8V~13.9V
    * OVER CURRENT PROTECTION
    * SHORT CIRCUIT PROTECTION
    * EMI : FCC CLASS B , CISPR 22 CLASS B
    * SAFETY:TO MEET UL, CUL, TUV
    * REMOTE ON / OFF CONTROL
    * FAULTY ALARM METHODS: TTL SIGNAL
    * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
    * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * REMOTE SENSING DESIGN
    * ISOLATION: BUILT-IN THE POWER MODULE
    * COOLING: TWO 40x40x28mm DC FANS
    * AC INLET IN EACH MODULE


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/S1MVMA00.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/S1M-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/S1M-V%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/S1M-V%20CCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/S1M-5550V(RoHS).pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/S1M-5550V%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/S1M-5550V%20FCC.pdf

    ご注文から納品までの流れ「発注方法がわからない」「納品までの流れがイメージできない」そんな不安を解消いたします!

    複数条件から探す

    メーカー、筐体サイズ、仕様(CPU、CPUソケット数、最大GPU数)、特長・用途などから製品を探せます。

    キーワードから探す

    CLOSE

    サーバー・産業用PCに関するご相談・お見積りなど
    お気軽にお問い合わせをください。

    03-3815-9001 受付時間/平日9:30 〜 18:00