電源 (Zippy)

    R3G-5950V4V(950W)

    製品仕様

    wattage950W
    solutionServer ,Workstation ,Storage System
    dimension_mm276x83x127
    dimension_inch10.87x3.27x5
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:8A/3A (115 / 230 VAC) POWER MODULE INRUSH CURRENT:35/70A MAX. FOR 115/230 VAC POWER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1 32 ±5% ±1% 50mV
    +12V 3 76 ±5% ±1% 120mV
    -12V 0.1 1.2 ±10% ±1% 150mV
    +3.3V 1 32 ±5% ±1% 50mV
    +5VSB 0.3 4 ±5% ±1% 50mV
    TOTAL CURRENT OF +5V AND +3.3V NOT EXCEED 190W
    TOTAL OUTPUT MAX: 950W


    features* TEMPERATURE RANGE:OPERATING 0℃~40℃
    * HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 60 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 60 SECOND
    * EFFICIENCY:82% TYPICAL AT 115VAC, FULL LOAD
    * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS
    * OVER POWER PROTECTION:110% ~ 180%
    * OVER VOLTAGE PROTECTION:+5V→5.9V~6.7V、+12V→13.0V~15.0V、+3.3V→3.9V~4.3V SHORT CIRCUIT PROTECTION:SHUT DOWN AND LATCH OFF
    * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
    * SAFETY: TO MEET UL, CUL, TUV, CCC
    * REMOTE ON/OFF CONTROL
    THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.
    * N+1 REDUNDANCY FUNCTION
    * HOT-SWAPPABLE FUNCTION
    * CURRENT/BALANCE LOAD SHARING DESIGN
    * +3.3V REMOTE SENSING
    * ISOLATION: BUILT-IN IN POWER MODULE
    * POWER FACTOR CORRENTION: ACTIVE (MEET IEC-1000-3-2)
    * COOLING: 40mm DC FANS (one module)


    * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/R3GVMA00.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/R2G%20&%20R3G%20Series2008.doc CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/GIN-3600V,R2G-V,R3G-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/GIN-3600V,R2G-V,R3G-V%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/GIN-3600V,R2G-V,R3G-V%20CCC.pdf MTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R3G-5950V4V(RoHS).pdf MTBFI(RoHS)(40℃)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R3G-5950V4V(RoHS)(40%e2%84%83)(NO%20FAN).pdf MTBFI(RoHS)(40℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R3G-5950V4V(RoHS)(40%e2%84%83).pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/GIN-3600V,R2G-V,R3G-V%20BSMI.pdf