電源 (Zippy)

    R3G-5800P4V(800W)

    製品仕様

    wattage800W
    solutionServer ,Workstation ,Storage System
    dimension_mm276x127x83
    dimension_inch10.87x5x3.27
    input_specVOLTAGE: 90 ~ 264 VAC FULL RANGE. FREQUENCY: 47 ~ 63 Hz. INRUSH CURRENT: 40A MAX. FOR 115 VAC PER MODULE 60A MAX. FOR 230 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 1 45 ±5% ±1% 50mV
    +12V 1.5 49 ±7% ±1% 120mV
    -12V 0.01 1 ±10% ±1% 120mV
    +3.3V 1 38 ±5% ±1% 50mV
    +5VSB 0.1 4 ±5% ±1% 50mV


    features* TEMPERATURE RANGE: OPERATING 0℃ --- 40℃,STORAGE -20℃ --- 70℃
    * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
    * DIELECTRIC WITHSTANDING: INPUT/OUTPUT 1500 VAC FOR 1 MINUTE
    INPUT TO FRAM GROUND 1500 VAC FOR 1 MINUTE
    * EFFICIENCY: 70% TYPICAL, AT FULL LOAD
    * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
    * OVER LOAD PROTECTION: 110 ~ 160% MAX
    * OVER VOLTAGE PROTECTION:
    +5V → 5.7V ~ 6.5V, +3.3V → 3.9V ~ 4.7V, +12V → 13.3V ~ 14.3V
    * SHORT CIRCUIT: 5V, 12V, 3.3V,AUTO-RECOVERED: 5VSB, -12V
    * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
    * SAFETY: MEET UL 60950, CSA 60950, TUV EN-60950
    * REMOTE ON / OFF CONTROL
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * 2+1, HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
    * N+1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
    * REMOTE SIGNAL DESIGN
    * ISOLATION: BUILT-IN THE POWER MODULE
    * COOLING: TWO 40 mm DC FANS (ONE IN EACH MODULE)


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfFCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/R3G-5800P4V%20FCC.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/R3G0MA21.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/R2G,R3G,R4G-5%e7%b5%84%20CB.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/R3G-5800P4V(RoHS).pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/R2G,R3G,R4G-5%e7%b5%84%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/R2G,R3G,R4G-5%e7%b5%84%20CCC.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/R3G.PDF MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/R2G%20&%20R3G%20Series2008.doc