電源 (Zippy)

    M3W-6950P(950W)

    製品仕様

    wattage950W
    solutionServer
    dimension_mm300x101x125
    dimension_inch11.81x3.98x4.92
    input_specVOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT(Power Module):4A(RMS)FOR 230VAC 8A(RMS)FOR 115VAC INRUSH CURRENT(Power Module):60A MAX. FOR 115 VAC PER MODULE 80A MAX. FOR 230 VAC PER MODULE
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 6 56 ±5% ±1% 70mV
    -5V 0.2 1.2 ±5%/-10% ±1% 120mV
    +12V 6 60 +6% ±1% 120mV
    -12V 0.2 1.2 +5%/-10% ±1% 120mV
    +3.3V 3.5 44 ±5% ±1% 70mV
    +5VSB 0.4 3.5 +5%/-6% ±1% 70mV
    POWER MODULE TOTAL CURRENT OF +5V AND +3.3V NOT EXCEED 40A
    POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 460W
    TOTAL OUTPUT POWER 2+1=950W


    features*TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~70℃
    *HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE
    *DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1minute
    INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
    *EFFICIENCY:68% TYPICAL,AT FULL LOAD
    *POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
    *OVERLOAD PROTECTION:110~160% MAX
    *OVER VOLTAGE PROTECTION:+5V→5.7V~6.5V,+3.3V→3.9V~4.3V ,+12V→13.3V~14.3V
    *OVER CURRENT PROTECTION
    *EMI : FCC CLASS B , CISPR 22 CLASS B
    *SAFETY:UL 1950, CSA 22.2 NO/950, TUV IEC 950
    *REMOTE ON / OFF CONTROL
    *FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    *MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
    *HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    *REMOTE SENSING DESIGN
    *ISOLATION: BUILT-IN THE POWER MODULE
    *COOLING: TWO 38x38x28mm DC FANS (MODULE)
    *AC INLET IN EACH MODULE


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1WX%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1WX%20TUV.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M3W-6950P.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1WX%20CCC%20AC%20IN%2020-10A.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M3W-6950P%20FCC.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M3W-6950P(RoHS).pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M3W0MA00.pdf Manual:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/MyWx%20Series.pdf

    ご注文から納品までの流れ「発注方法がわからない」「納品までの流れがイメージできない」そんな不安を解消いたします!

    複数条件から探す

    メーカー、筐体サイズ、仕様(CPU、CPUソケット数、最大GPU数)、特長・用途などから製品を探せます。

    キーワードから探す

    CLOSE

    サーバー・産業用PCに関するご相談・お見積りなど
    お気軽にお問い合わせをください。

    03-3815-9001 受付時間/平日9:30 〜 18:00