電源 (Zippy)

    M1W4-6D50P(1350W)

    製品仕様

    wattage1350W
    solutionServer ,Workstation ,Storage System ,Communication ,Networking
    dimension_mm340x422x42
    dimension_inch13.39x16.61x1.65
    input_specVOLTAGE: 100V ~ 240VAC (WITH ± 10% TOLERANCE) FREQUENCY: 47Hz ~ 63Hz INPUT CURRENT: 20-10A MAX AT ANY LOW/HIGH INPUT VOLTAGE INRUSH CURRENT: 60/100A @ 115/230VAC (25℃) POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    5V 6.0 84.5 ± 5% ± 50mV 70mV
    12V 6.0 90 ± 6% ± 50mV 120mV
    -5V 0.2 1.2 +5%, -10% ± 50mV 120mV
    -12V 0.2 1.2 +5%, -10% ± 50mV 120mV
    3.3V 3.5 67.5 ± 5% ± 50mV 70mV
    +5VSB 0.4 3.5 +5%, -6% ± 50mV 70mV
    * POWER MODULE TOTAL CURRENT OF +5V AND +3.3V NOT EXCCED 40A
    * POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 500W
    * TOTAL OUTPUT POWER 3+1=1350W


    features‧TEMPERATURE RANGE: OPERATING: 0℃ ~ 40℃; STORAGE: -20℃ ~ 80℃
    ‧HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    ‧REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    ‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
    ‧DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
    INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
    ‧EFFICIENCY: 67% TYPICAL AT 115VAC FULL LOAD
    POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
    ‧OVER POWER PROTECTION: 110% ~ 150%
    ‧OVER VOLTAGE PROTECTION: +5V ->5.7V ~ 6.5V, 3.3V -> 3.9V ~ 4.7V,+12V -> 13.3V ~ 14.3V
    ‧OVER CURRENT PROTECTION: 110% ~ 180%
    ‧SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
    ‧EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
    ‧SAFETY: UL&CUL, TÜV


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/M1WX%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/M1WX%20TUV.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/M1W4-6D50P%20FCC.pdf MTBF:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1W4-6D50P.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/M1WX%20CCC%20AC%20IN%2020-10A.pdf DRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/M1W4MA01.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/M1W4-6D50P(RoHS).pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/MyWx%20Series.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/M1W4-6D50P%20(+Radiation).pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/BSMI/M1W,M2W,M1W4%20BSMI.pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/