電源 (Zippy)

    BB1U-6150V(150W)

    製品仕様

    wattage150W
    solutionWorkstation ,IPC ,PCs ,Communication ,Networking
    dimension_mm152x84x39
    dimension_inch5.98x3.31x1.54
    input_specVOLTAGE: 18 ~ 36VDC INPUT CURRENT:10A/5A at any low/high range input voltage. INRUSH CURRENT:15Amps (MAX)@ 36 VDC (at 25 degrees ambient cold start )
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0 14 ±5% ±1% 50mV
    +12V 0.1 12 ±5% ±1% 120mV
    -12V 0 0.5 ±5% ±1% 120mV
    +3.3V 0 12 ±5% ±1% 50mV
    +5VSB 0 1.5 ±5% ±1% 50mV
    -5V 0 0.3 ±5% ±1% 100mV
    * -5V is option and we did not put -5V in our standard model.
    +5V and +3.3V total output max : 70W(with 10CFM)
    +5V and +3.3V total output max : 50W(without FAN)
    Total Output Power : 150W(with 10CFM)
    Total Output Power : 120W(without FAN)


    features* TEMPERATURE RANGE:OPERATING 0℃~70℃ (18~36VDC); NON-OPERATING TEMPERATURE: -20℃~80℃
    * HOLD UP TIME:2mS MINIMUM AT 10V FULL LOAD (DC18V)
    * LEAKAGE CURRENT: 3.5MA MAX. AT NOMINAL VOLTAGE 36VDC
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND
    * EFFICIENCY:82%(+/-2%) AT 18VDC/24VDC IN AND LOAD CONDITION; 12V/6.12A; 5V/4.98A; 3.3V/4.27A; -12V/0.39A; 5VSB/0.56A
    * OVER POWER PROTECTION: 110~160% MAX
    * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V
    * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
    * SAFETY : TO MEET UL, CUL, TUV, CCC


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfCB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/AB1U-V%20&%20BB1U-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/AB1U-V%20&%20BB1U-V%20TUV.pdf MTBF(RoHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/BB1U-6150V(RoHS).pdf MTBF(RoHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/BB1U-6150V(RoHS)(50%e2%84%83).pdf CE (Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/BB1U-6150V%20(Radiation).pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/BB1U-6150V%20FCC.pdf