電源 (Zippy)

    AB1U-5120V(120W)

    製品仕様

    wattage120W
    solutionWorkstation ,IPC ,PCs ,Communication ,Networking
    dimension_mm152x84x39
    dimension_inch5.98x3.31x1.54
    input_specVOLTAGE: 10 ~ 36VDC FREQUENCY: DC INPUT CURRENT:14.5A/4A at any low/high range input voltage. INRUSH CURRENT:15Amps (MAX)@ 36 VDC (at 25 degrees ambient cold start )
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0 14 ±5% ±1% 50mV
    +12V 0.1 8 ±5% ±1% 120mV
    -12V 0 0.5 ±5% ±1% 120mV
    +3.3V 0 12 ±5% ±1% 50mV
    +5VSB 0 1.5 ±5% ±1% 50mV
    * +5V and +3.3V total output max : 70W(with 20CFM)
    * +5V and +3.3V total output max : 50W(without FAN)
    * Total Output Power : 120W(with 20CFM)
    * Total Output Power : 86W(without FAN)




    features* TEMPERATURE RANGE:OPERATING 0℃~50℃
    * HOLD UP TIME:2mS MINIMUM AT 10V FULL LOAD
    * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND
    * EFFICIENCY:82% TYPICAL,AT FULL LOAD 12Vdc
    * OVER POWER PROTECTION:110~160% MAX
    * OVER VOLTAGE PROTECTION
    * SHORT CIRCUIT PROTECTION
    * SAFETY : TO MEET UL, CUL, TUV
    * REMOTE ON/OFF CONTROL
    THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY).
    AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.
    * MEET IEC-1000-3-2 CLASS D


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfDRAWING:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/DRAWING/AB1UMA00.pdf short form:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/SHORT%20FORM/AB1U-5120V.pdf MTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/AB1U-5120V(RoHS).pdf MTBF(ROHS)(70℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/AB1U-5120V(RoHS)(70%e2%84%83).pdf MTBF(ROHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/AB1U-5120V(RoHS)(50%e2%84%83).pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/AB1U-V%20&%20BB1U-V%20CB.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/AB1U-V%20&%20BB1U-V%20TUV.pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/AB1U-V%20&%20BB1U-V%20CCC.pdf CE:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/AB1U-5120V%20(+Radiation).pdf