電源 (Zippy)

    HG2-5400V(400W)

    製品仕様

    wattage400W
    solutionServer ,Workstation ,PCs
    dimension_mm140x150x86
    dimension_inch5.51x5.91x3.39
    input_specVOLTAGE: 90~240 VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT: 6A/3A FOR 115/230VAC INRUSH CURRENT: 20/40 MAX. FOR 115/230VAC
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V 0.5 20 ±5% ±50mV 50mV
    +12V 1 30 ±5% ±50mV 120mV
    -12V 0 0.8 ±5% ±50mV 120mV
    +3.3V 0.5 20 ±5% ±50mV 50mV
    +5VSB 0.1 3.5 ±5% ±50mV 50mV


    features*TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃; STORAGE -20℃ ~ 80℃
    *HOLD UP TIME: 16ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
    *EFFICIENCY: 80-85% TYPICAL AT 115V FULL LOAD
    *POWER GOOD SIGNAL: ON DELAY 100ms TO 500ms, OFF DELAY 1ms
    *OVER POWER PROTECTOIN
    *OVER VOLTAGE PROTECTOIN
    *SHORT CIRCUIT PROTECTION
    *OVER CURRENT PROTECTION
    *SAFETY: TO MEET UL, CUL, TUV, CCC


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
    pdfMTBF(ROHS):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/HG2-5400V(RoHS).pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/HG2-V%20&%20GP2-V%20TUV.pdf CB:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CB/HG2-V%20&%20GP2-V%20CB.pdf BSMI:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/ 80+ report:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/REPORT/EMACS-HG2-5400V-400W-Report.pdf TUV:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/TUV/HG2-V%20&%20GP2-V%20TUV.pdf FCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/FCC/HG2-5400V%20FCC.pdf MANUAL:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MANUAL/HG2-HP2-PSM-PSL%20SERIES%20MAUNAL(English).pdf MTBF(ROHS)(50℃):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/HG2-5400V(RoHS)(50%e2%84%83).pdf MTBF(ROHS)(50℃)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/HG2-5400V(RoHS)(50%e2%84%83)(NO%20FAN).pdf MTBF(RoHS)(NO FAN):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/MTBF/HG2-5400V(RoHS)(NO%20FAN).pdf CE(Radiation):http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CE/HG2-5400V%20(Radiation).pdf CCC:http://www.zippy.com.tw//backend/DownLoad/DownLoad/Power/CCC/HG2-V%20&%20GP2-V%20CCC.pdf