電源 (Zippy)

    DR1S2-5307V4V(300W)

    製品仕様

    wattage300W
    solutionServer ,Workstation ,Storage System ,IPC ,Communication ,Networking
    dimension_mm275.5x135x83.1
    dimension_inch10.85x5.31x3.27
    input_specVOLTAGE:-36 ~ -72VDC (NORMAL -48VDC) FREQUENCY: DCSTEADY-STATE CURRENT: 12A/6A MAXIMUN AT ANY LOW/HIGH RANGE INPUT VOLTAGEINRUSH CURRENT: 70A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START)
    dc_output
    Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
    +5V1 0.5 20 ±5% ±1% 50mV
    +5V2 0.5 20 ±5% ±1% 120mV
    +12V 2.0 24 ±5% ±1% 120mV
    -12V 0.1 0.5 ±10% ±1% 50mV
    +5VSB 0.1 2.5 ±5% ±1% 50mV
    * POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 140W
    * TOTAL OUTPUT MAX 380W
    * WHEN CONDITIONS OF BOTH +5V/0A & +3.3V/0A, MIN LOAD OF 4A AT +12V IS A MUST


    features* TEMPERATURE RANGE:OPERATING 0℃~50℃, STOREAGE -20℃~80℃
    * HOLD UP TIME:1.6mS MIN.
    * EFFICIENCY: TYPICAL >80% AT -48VDC, FULL LOAD
    * OVER POWER PROTECTION: 110~160%
    * OVER VOLTAGE PROTECTION:+5V1→5.6V~6.7V,+5V2→5.6V~6.7V,+12V→13V~17V
    * SHORT CIRCUIT PROTECTION: +5V1, +5V2, +12V, -12V
    * REMOTE ON/OFF CONTROL
    * REMOTE SENSING DESIGN
    * BALANCE LOAD SHARING DESIGN
    * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    * SAFETY:MEET UL, CUL, TUV, CCC


    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.